Sysmex Suisse
Sysmex Europe
Support
Other Sites
Menu

CyFlow Cube 8

  • Flow Cytometer for all applications in cell analysis and absolute counting
  • 8 optical parameters
  • 6 fluorescence channels

CyFlow Cube 8

This internationally awarded, truly stand-alone Flow Cytometer is ultra-compact and uniquely designed for all applications in cell analysis and absolute counting. With the CyFlow Cube 8, accurate flow cytometry is offered by employing 8 optical parameters within an instrument size of only 50x47x35.5 cm. Forward Scatter (FSC) and Side Scatter (SSC) work in combination with 6 fluorescence channels (FL1-FL6). An optional, built-in CyFlow® Sorter module for diamond-piezo-based, closed, non-destructive and non-hazardous cell and particle sorting is available.

Highlights

Highlights

  • High-performance, bench-top design with fully-integrated fluidics, built-in PC, and a 19" TFT monitor
  • Choice of 488, 638, 407, 355, 375, 532, 561, 594, 785 nm lasers
  • Optional high power 365 nm UV LED for highest resolution DNA analysis with CV ≤ 1%
  • Superior fluorescence sensitivity: ≤ 100 MESF (FITC) | ≤ 50 MESF (PE)
  • Superior nanotechnology: small particle detection <50 nm
  • Flexible and modular CyFlow Cube system configurations
  • Optional CyFlow Sorter for closed, non-destructive, non-hazardous cell and particle sorting with the highest purity
  • Optional CyFlow Robby autoloader for well plates and tubes
  • Unique price/performance ratio
Optionen

Optionen

  • Optional CyFlow Robby 8 Autoloading Station for well plates and tubes
  • Optional CyFlow Sorter for closed, non-destructive cell and particle sorting with high purity

 

 

 

Specification

Specification

Light Sources: 

  • Up to 4 light sources (3 laser + high power UV-LED)
  • Blue laser: 50mW @488nm, 200mW adjustable @488nm
  • Red laser: 25mW @638nm, 40mW @640nm
  • Violet laser: 100mW @405nm
  • UV laser: 60mW @375nm
  • Green laser: 30mW @532nm, 100mW @532nm
  • Yellow laser: 100mW @561nm
  • Orange laser: 50mW @594nm
  • High power UV-LED: 365nm

 

Optics:

  • Modular optical system with selected PMTs with integrated electronic preamplifier for FSC, SSC, FL1-FL6
  • Exchangeable optical filters

 

Flow System:

  • Quartz flow cuvette for laminar sample transport and hydrodynamic focussing
  • True Volumetric Absolute Counting (TVAC) based on mechanical volume measurement
  • Computer controlled precision syringe pump for sample transport, speed continuously adjustable from 0-20 µl/sec.

 

Software:

  • Windows™ based FCM software CyView for real-time data acquisition, real-time data analysis and real-time data display
  • Easy experimental template set up (configuration files)
  • Flow Cytometry Standard (FCS) data format for storage of original and evaluated data

 

Dimensions:

  • L 500mm x W 470mm x H 370mm
  • With Autoloading Station: L 840mm 
Upgrade

Upgrade

CyFlow Robby 8 Autoloading Station 

General Facts:

  • Protective housing with no light incidence
  • Flexible well/tube measurements 

 

Microplates and tubes:

  • 48 or 96-Well-Plates, V, U and flat-bottom can be used (max.2)
  • Plates meeting the Standards (ANSI/SLAS 1-2004 through 4-2004)
  • 2ml tubes (max. 120)

 

Analysed Volume:

  • Flexible choice of sample volume up to 180 µl for plates and 2000 µl for tubes

 

Speed:

  • Continuously adjustable from 0.2 µl/sec. to 10 µl/sec. 
  • ~ 1h for 96-Well-Plate (speed 2 µl/sec., sample volume 20 µl)

 

Software:

  • CyView windows based software 

 

Dimensions: 

  • L 370mm x W 332mm x H 370mm

CyFlow Cube 8 Sorter 

General Facts:

  • Configurations with up to 5 optical parameters (up to 3 colours)
  • Sterile sorting by closed fluidic system
  • Optional CyFlow Robby 8 Autoloading Station for well plates and tubes 

 

Light Sources:

  • Up to 2 simultaneous light sources (laser) 
  • Blue laser: 50mW @488nm, 200mW adjustable @488nm
  • Red laser: 25mW @638nm, 40mW @640nm
  • Violet laser: 100mW @405nm
  • UV laser: 60mW @375nm
  • Green laser: 30mW @532nm, 100mW @532nm
  • Yellow laser: 100mW @561nm
  • Orange laser: 50mW @594nm

 

Optics:

  • Modular optical with selected PMTs with integrated electronic preamplifier for FSC, SSC, FL1-FL3
  • Exchangeable optical filters

 

Flow System:

  • Quartz sorter cuvette for laminar sample transport and sorting process
  • Completely closed and integrated fluidic system 
  • Sample port with biosafety cleaning system
  • True Volumetric Absolute Counting (TVAC) based on mechanical volume measurement 
  • Computer controlled precision syringe pump for sample transport, speed continuously adjustable from 0-20µl/sec. 

 

Software:

  • Windows™ based FCM software CyView for real-time data acquisition, real-time data analysis and real-time data display 
  • Easy experimental template set up (configuration files)
  • Flow Cytometry Standard (FCS) data format for storage of original and evaluated data 

Dimensions: 

  • L 500mm x W 470mm x H 370mm
    (without sorting module) 
PDF erstellen
Erkunden Sie das Media Center
Gesamt
  • Gesamt
  • Dokumente
  • Podcast
  • Bilder
  • Videos
Sysmex Urinalysis
Sysmex XN – TAILORING YOUR HAEMATOLOGY
Erleben Sie den XN
Sysmex XN – TAILORING YOUR HAEMATOLOGY Erleben Sie den XN https://www.sysmex.ch/media-center/xn-tailoring-your-haematology-2880.html#
Unsere Sammlung https://www.sysmex.ch/akademie/literatur/sysmex-xtra.html
Erweitern Sie Ihr Wissen https://www.sysmex.ch/akademie/literatur/sysmex-xtra.html
Blutausstriche Bildergallerie https://www.sysmex.ch/akademie/literatur/bilddatenbank.html
Mehr zum Design Konzept https://www.sysmex.ch/unternehmen/silent-design.html
Sysmex XN – TAILORING YOUR HAEMATOLOGY Erleben Sie den XN https://www.sysmex.ch/media-center/xn-tailoring-your-haematology-2880.html#