CytoSure Constitutional v3 and v3 +LOH arrays
The only array with the latest ID/DD gene content (ClinGen/DDD)
- High-resolution CNV detection in up to 502 genes of interest
- Accurate identification of CNVs, LOH, UPD and consanguineous samples
- Integrated sample tracking probes and optimised labelling kits
- Streamlined data analysis and interpretation of CNVs and LOH with complimentary Interpret NGS Analysis Software
Developmental delay (DD)/intellectual disability (ID), characterised by a significant impairment of cognitive and adaptive functions, affects 1–3% of the population, yet the majority of these patients remain undiagnosed. The aetiology of DD/ID is heterogeneous as it is influenced by both genetic and environmental factors. High-resolution G-banded karyotyping reveals chromosome abnormalities in 3–5 % of patients, and molecular cytogenetics, e.g. fluorescence in situ hybridisation (FISH), provides diagnosis in an additional 3–6% of cases. In the past few years, the application of aCGH and single-nucleotide polymorphism (SNP) arrays has revolutionised the clinical research of DD/ID. [1]
The CytoSure® Constitutional v3 arrays deliver enhanced exon-level coverage of developmental disorder genes. They combine the up-to-date and relevant developmental delay content from the recent Deciphering Developmental Disorders (DDD) study and latest content from ClinGen. The addition of a research-validated collection of single-nucleotide polymorphism (SNP) probes with the CytoSure Constitutional v3 +LOH array enables precise identification of loss of heterozygosity (LOH) and uniparental disomy (UPD) in addition to accurate copy number (CN) detection. This offers cost-effective detection of a broader range of genetic syndromes – with no need for additional investment in equipment or training.
Ready to move your DD/ID research to the next level? Check our Constitutional NGS solution.
References
[1] Bartnik, M., Nowakowska, B., Derwińska, K. et al. Application of array comparative genomic hybridization in 256 patients with developmental delay or intellectual disability. J Appl Genetics 55, 125–144 (2014). https://doi.org/10.1007/s13353-013-0181-x
Disclaimer
CytoSure®: for research use only, not for use in diagnostic procedures. Product availability may vary from country to country. Contact your local representatives for availability.
Manufacturer and Trademarks: CytoSure® (Oxford Gene Technology IP Limited)
| Product | Cat. No. | Top priority genes | Medium priority genes | Lower priority genes | Decipher Syndrome regions | ClinGen regions | High priority backbone resolution | Medium priority backbone resolution | Lower priority backbone resolution |
| CytoSure Constitutional v3 (8x60k) | CYA0245 | Exon targeted | Whole-gene targeted | Whole-gene targeted | Whole-gene targeted | Whole-gene targeted | 189kb (1 probe every ~63kb) | 375kb (1 probe every ~125kb)) | 663kb (1 probe every ~221kb)) |
| CytoSure Constitutional v3 (4x180k) | CYA0246 | Exon targeted | Exon targeted | Exon targeted | Whole-gene targeted | Whole-gene targeted | 68kb (1 probe every ~22kb) | 74kb (1 probe every ~ 24kb) | 162kb (1 probe every ~54kb) |
CytoSure Constitutional +LOH (4x180k) | CYA0247 | Exon targeted | Whole-gene targeted | Whole-gene targeted | Whole-gene targeted | Whole-gene targeted | 68kb (1 probe every ~22kb) | 74kb (1 probe every ~24kb) | 162kb (1 probe every ~54kb) |
Table 1. Selection guide for CytoSure Constitutional v3 arrays. For a complete list of genes covered, please contact your local Sysmex representative.
CytoSure Interpret Software requirements:
| Requirement | Minimum | Recommended |
| Memory (RAM) | 16 GB | 24 GB |
| CPU Cores | 8 | 16 |
| Storage (Disk space) | 500 GB | 2 TB |
| Operating System | Windows 7 or newer | Windows 7 or newer |
| Other | Virualisation (VT-x) to be enabled in the BIOS | Virualisation (VT-x) to be enabled in the BIOS |
The recommended IT requirements results in one-hour analysis time for each sample
Sysmex Suisse AG
Tödistrasse 50
CH-8810 Horgen
+41 44 718 38 38
+41 44 718 38 39
Sysmex Suisse AG
Rue Galilée 15
CH-1400 Yverdon-les-Bains
+41 24 423 93 93
+41 24 423 93 98
Documents produit
Documents réglementaires
Vous pouvez accéder aux documents produits ainsi qu’aux documents réglementaires, tels que les modes d’emploi, avec votre compte dans notre portail clients.
Vers My Sysmex
